We are instrumental in offering quality Portable Kits to our clients. These are offered in two specifications, which is either digital or micro-processor based.
The digital kit offered by us is used for testing pH, conductivity, temperature, DO, TDS & salinity of a solution. Further, the micro-processor based kits are also used for determining pH, conductivity, temperature, DO, TDS & salinity. We offer our range of Portable Kits with LCD & TFT displays that eases the tracking and recording of the above measuring entities.
Features:
- 16x2 alpha numeric backlit LCD display
- Temperature and parameter display simultaneously
- Real time display in 24 hour format
- Simple menu driven controls using soft keys
- Storage upto 1000 samples
- 230 V + 10% 50 Hz with inbuilt 12V rechargeable battery
- Serial RS-232 and parallel centronics computer interface
- Print selection - datewise or all data
Technical Specifications:
G-5020 | pH | Conductivity | TDS | DO | mV/ORP | Salinity | Temperature | Turbidity * |
Range | 0 to 14 pH | 0.00 µS/cm to 1000 mS/cm in 6 Auto Ranges | 0.00 ppm to 200 ppt in 5 Auto ranges | 0 to 20 ppm | -1999 to +1999 mV | 0 tp 50 ppt | -20 °C to 200 °C | 0 to 1000 NTU in 2 ranges |
Resolution | 0.01 pH | 0.01, 0.1,1 µS/cm or mS/cm as per range | 0.01, 0.1, 1 ppm or ppt as per range | 0.1 ppm | 1 mV | 0.2 ppt | 0.1 °C | 0.1 NTU in lowest range |
Accuracy | +0.01 pH | +0.5% | +0.5% | +0.2 ppm +1 digit | +0.2 ppm +1 digit | +0.5% | +0.2% + 1digit | +3%FS +1 digit |
Calibration | Auto & Manual | ---- | ---- | Auto & Manual | Auto & Manual | ---- | Manual | Manual |
Temperature Compensation | 0-100 °C (Auto/Manual) | 0-100 °C (Auto/Manual) | ---- | ---- | 0-100 °C (Auto/Manual) | |||
Auto Buffer Recognition | 4.00, 7.00 & 9.20 | ---- | ---- | ---- | ---- | ---- | ---- | ---- |
Range Selection | ---- | Automatic | Automatic | ---- | ---- | ---- | ---- | Automatic |
Cell Constant Adjustment | ---- | 0.05 to 2.0 (Auto/Manual) | 0.05 to 2.0 (Auto/Manual) | ---- | ---- | ---- | ---- | ---- |
Temperature Coefficient | ---- | 0-4% adjustable | ---- | ---- | ---- | ---- | ---- | ---- |
Salinity Factor | ---- | ---- | ---- | ---- | ---- | ---- | ---- | ---- |
TDS Factor | ---- | ---- | adjustable(0.5 by default) | ---- | ---- | ----- | ---- | ---- |
Salinity Correction | ---- | ---- | ---- | 0 to 20 mg/L | ---- | ----- | ---- | ---- |
Standard Accessories: pH Electrode, Buffer solutions (4.00, 7.00 & 9.20), Conductivity/TDS/Salinity Cell, DO Probe, DO Membrane & KCL, Temperature Probe, ORP Electrode (at extra cost), Operation Manual, Data cable
* Turbidity is available in Model G-5021 with following additional specifications:
- Sample System: 30 mm clear glass test tube
- Light Source: 6V tungsten lamp
- Detector: Photodiode/photocell
Appearance and specification subject to change due to continuous development.